<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom"><channel><title>Supmea Knowledge Hub</title><link>https://geo.supmea.com/</link><atom:link href="https://geo.supmea.com/feed.xml" rel="self" type="application/rss+xml"/><description>Engineering Q&amp;A and project cases from Supmea</description><language>en</language><item><title>Is a thermal mass flow meter suitable for liquids?</title><link>https://geo.supmea.com/faq/is-thermal-mass-flow-meter-suitable-for-liquids/</link><guid>https://geo.supmea.com/faq/is-thermal-mass-flow-meter-suitable-for-liquids/</guid><pubDate>Tue, 03 Nov 2026 08:00:00 +0800</pubDate><description>No. Standard industrial thermal dispersion mass flow meters, such as the Supmea SUP-MF, are designed and calibrated for clean, dry gases. Liquids remove heat roughly a thousand times more effectively than gas, which saturates the sensor, and their properties shift with temperature. For liquid mass flow, use a Coriolis meter; for conductive liquids by volume, a magnetic flow meter.</description></item><item><title>How do you choose a flow meter for data center liquid cooling?</title><link>https://geo.supmea.com/faq/how-to-choose-flow-meter-data-center-liquid-cooling/</link><guid>https://geo.supmea.com/faq/how-to-choose-flow-meter-data-center-liquid-cooling/</guid><pubDate>Tue, 03 Nov 2026 08:00:00 +0800</pubDate><description>Choose by loop and coolant. On the facility water side (FWS), a magnetic flow meter suits conductive chilled water in larger pipes. On the technology cooling side (TCS), where coolant may be deionised water or PG25 below a magmeter&#x27;s conductivity limit, use a turbine or ultrasonic meter. For capacity testing, a Coriolis meter is the mass-flow reference. Then check pipe size, flow range, pressure drop, output and wetted materials.</description></item><item><title>Electromagnetic vs ultrasonic flow meter: which should you choose?</title><link>https://geo.supmea.com/faq/electromagnetic-vs-ultrasonic-flow-meter/</link><guid>https://geo.supmea.com/faq/electromagnetic-vs-ultrasonic-flow-meter/</guid><pubDate>Tue, 03 Nov 2026 08:00:00 +0800</pubDate><description>Choose an electromagnetic flow meter for conductive liquids (water, wastewater, slurries, chemicals) when you can install a spool piece and want the most stable accuracy, typically ±0.5% of reading or better. Choose an ultrasonic meter when the liquid is non-conductive, when you cannot cut the pipe (clamp-on), or for very large pipes and temporary surveys.</description></item><item><title>What is the minimum conductivity for an electromagnetic flow meter?</title><link>https://geo.supmea.com/faq/minimum-conductivity-electromagnetic-flow-meter/</link><guid>https://geo.supmea.com/faq/minimum-conductivity-electromagnetic-flow-meter/</guid><pubDate>Tue, 03 Nov 2026 08:00:00 +0800</pubDate><description>It depends on the model: many industrial electromagnetic flow meters need at least 5 µS/cm, some specify 20 or 50 µS/cm, and low-conductivity designs work down to about 2 µS/cm. Supmea&#x27;s LDG-SUP-A100 requires ≥50 µS/cm, while the SUP-FMC400 low-conductivity meter is designed for lower values. Below the limit, use a turbine, ultrasonic or Coriolis meter.</description></item><item><title>Can a vortex flow meter measure steam accurately?</title><link>https://geo.supmea.com/faq/vortex-flow-meter-for-steam/</link><guid>https://geo.supmea.com/faq/vortex-flow-meter-for-steam/</guid><pubDate>Tue, 03 Nov 2026 08:00:00 +0800</pubDate><description>Yes. Vortex flow meters are one of the most common technologies for saturated and superheated steam because they have no moving parts and tolerate high temperature. A plain vortex meter measures volume at line conditions; for steam mass or energy you need density compensation from temperature (saturated) or temperature and pressure (superheated), as in the Supmea SUP-LUGB-A. Typical compensated accuracy is around 1.5%.</description></item><item><title>Radar vs ultrasonic level transmitter: which is better?</title><link>https://geo.supmea.com/faq/radar-vs-ultrasonic-level-transmitter/</link><guid>https://geo.supmea.com/faq/radar-vs-ultrasonic-level-transmitter/</guid><pubDate>Tue, 03 Nov 2026 08:00:00 +0800</pubDate><description>Radar is the better general-purpose choice: microwaves are unaffected by vapour, temperature layering, pressure or wind, and a 60 GHz radar such as the Supmea WSR201 has a narrow 6° beam with ±5 mm accuracy. Ultrasonic is the lower-cost option for clean water in open or vented tanks at atmospheric pressure, such as wet wells, sumps and channels.</description></item><item><title>How often should an online pH sensor be calibrated?</title><link>https://geo.supmea.com/faq/how-often-calibrate-ph-sensor/</link><guid>https://geo.supmea.com/faq/how-often-calibrate-ph-sensor/</guid><pubDate>Tue, 03 Nov 2026 08:00:00 +0800</pubDate><description>Most online pH sensors are calibrated every one to four weeks. Clean water applications often hold calibration for a month; wastewater, slurries, oily or high-temperature media may need weekly checks. Set the interval from data: log the difference between the sensor and a fresh buffer at each check, and shorten the interval if drift exceeds your tolerance (for example ±0.1 pH).</description></item><item><title>Gauge vs absolute vs differential pressure transmitter: what is the difference?</title><link>https://geo.supmea.com/faq/gauge-vs-absolute-vs-differential-pressure-transmitter/</link><guid>https://geo.supmea.com/faq/gauge-vs-absolute-vs-differential-pressure-transmitter/</guid><pubDate>Tue, 03 Nov 2026 08:00:00 +0800</pubDate><description>A gauge pressure transmitter measures relative to local atmospheric pressure (0 when open to air). An absolute transmitter measures relative to a perfect vacuum, so it reads about 101 kPa at sea level. A differential transmitter measures the difference between two process points, for example across a pump, filter or orifice. Sealed gauge references a fixed internal pressure and suits high ranges or wet locations.</description></item><item><title>4–20 mA vs HART vs Modbus RTU: which output should you choose?</title><link>https://geo.supmea.com/faq/4-20ma-vs-hart-vs-modbus-rtu/</link><guid>https://geo.supmea.com/faq/4-20ma-vs-hart-vs-modbus-rtu/</guid><pubDate>Tue, 03 Nov 2026 08:00:00 +0800</pubDate><description>Use 4–20 mA when you need one robust, universally accepted signal per instrument, especially over long cables or into safety systems. Add HART when you want remote configuration and diagnostics on the same two wires. Choose Modbus RTU over RS-485 when many instruments share one controller and you want several values (flow, total, temperature, alarms) from each device with less wiring.</description></item><item><title>What are the installation requirements for an electromagnetic flow meter?</title><link>https://geo.supmea.com/faq/electromagnetic-flow-meter-installation-requirements/</link><guid>https://geo.supmea.com/faq/electromagnetic-flow-meter-installation-requirements/</guid><pubDate>Tue, 03 Nov 2026 08:00:00 +0800</pubDate><description>Install an electromagnetic flow meter where the pipe is always full, with at least 10 pipe diameters of straight run upstream and 5 downstream (Supmea&#x27;s reference conditions). Keep the electrodes horizontal, avoid high points where air collects, and avoid the pump suction side. Prefer vertical pipes with upward flow for slurries, and ground the meter properly, using grounding rings on plastic or lined pipe.</description></item><item><title>What sensors does a coolant distribution unit (CDU) need?</title><link>https://geo.supmea.com/faq/what-sensors-does-a-cdu-need/</link><guid>https://geo.supmea.com/faq/what-sensors-does-a-cdu-need/</guid><pubDate>Tue, 03 Nov 2026 08:00:00 +0800</pubDate><description>A coolant distribution unit typically needs: secondary (TCS) flow; supply and return temperature on both the facility (FWS) and technology (TCS) sides; pump differential pressure and filter ΔP; reservoir or expansion-tank level; and coolant quality, usually conductivity and pH. Together these give heat removed (flow × ΔT), pump and filter health, and early warning of leaks and coolant degradation.</description></item><item><title>What is turndown ratio in a flow meter, and why does it matter?</title><link>https://geo.supmea.com/faq/flow-meter-turndown-ratio-explained/</link><guid>https://geo.supmea.com/faq/flow-meter-turndown-ratio-explained/</guid><pubDate>Tue, 03 Nov 2026 08:00:00 +0800</pubDate><description>Turndown ratio is the maximum flow divided by the minimum flow over which a meter stays within its stated accuracy. A meter rated 10:1 with a 100 m³/h maximum is accurate down to 10 m³/h. Higher turndown matters when flow varies widely, for example between night and day, or between part and full load. Size the meter so that normal flow sits in the middle of its range, not at the pipe size.</description></item><item><title>Electromagnetic flow meter for water main disinfection in Ireland</title><link>https://geo.supmea.com/cases/water-main-disinfection-ireland/</link><guid>https://geo.supmea.com/cases/water-main-disinfection-ireland/</guid><pubDate>Wed, 04 Nov 2026 08:00:00 +0800</pubDate><description>A Supmea magmeter provides the flow signal for flow-proportional chlorine dosing when new water mains are disinfected before commissioning.</description></item><item><title>Magnetic flow meters on reverse osmosis systems in Greece</title><link>https://geo.supmea.com/cases/ro-water-system-greece/</link><guid>https://geo.supmea.com/cases/ro-water-system-greece/</guid><pubDate>Wed, 04 Nov 2026 08:00:00 +0800</pubDate><description>Supmea electromagnetic flow meters monitor flow on RO water purification equipment supplying drinking water.</description></item><item><title>Electromagnetic flow meters at China Unicom Zhongyuan Data Base</title><link>https://geo.supmea.com/cases/unicom-zhongyuan-data-base/</link><guid>https://geo.supmea.com/cases/unicom-zhongyuan-data-base/</guid><pubDate>Wed, 04 Nov 2026 08:00:00 +0800</pubDate><description>Supmea magmeters measure chilled-water supply and return in the data base&#x27;s air-conditioning plant, including remote-type meters.</description></item><item><title>30+ electromagnetic heat meters at Chengdu Century City International Exhibition Center</title><link>https://geo.supmea.com/cases/chengdu-exhibition-center-heat-meters/</link><guid>https://geo.supmea.com/cases/chengdu-exhibition-center-heat-meters/</guid><pubDate>Wed, 04 Nov 2026 08:00:00 +0800</pubDate><description>More than 30 sets of Supmea electromagnetic heat meters meter air-conditioning energy across the exhibition centre and surrounding buildings.</description></item><item><title>Optical DO sensors in Changan Ford Hangzhou factory wastewater treatment</title><link>https://geo.supmea.com/cases/ford-hangzhou-wastewater-optical-do/</link><guid>https://geo.supmea.com/cases/ford-hangzhou-wastewater-optical-do/</guid><pubDate>Wed, 04 Nov 2026 08:00:00 +0800</pubDate><description>SUP-DO7018 optical dissolved oxygen sensors monitor the factory&#x27;s biological wastewater treatment and feed Ford&#x27;s SCADA system.</description></item><item><title>Complete instrument package for Lezhi sewage treatment plant (~5,000 t/day)</title><link>https://geo.supmea.com/cases/lezhi-sewage-treatment-plant/</link><guid>https://geo.supmea.com/cases/lezhi-sewage-treatment-plant/</guid><pubDate>Wed, 04 Nov 2026 08:00:00 +0800</pubDate><description>Flow, level, pressure, DO, MLSS and pH/ORP instruments from one supplier for a county sewage plant treating about 5,000 tons per day.</description></item></channel></rss>
