SUP-PE100 Compact Pressure Transmitter
The SUP-PE100 is a compact diffused-silicon pressure transmitter for gauge, absolute or sealed pressure from −100 kPa to 60 MPa, in accuracy classes 0.2, 0.25 or 0.5. It has a 316L wetted diaphragm, EPDM or FKM seals, outputs from 4–20 mA to 0.5–4.5 V and RS485 Modbus, and a T90 response of 10 ms or less. It is designed for data center liquid cooling, HVAC and pump skids.
What it does
Liquid-cooling equipment needs pressure sensing in tight spaces: across pumps, filters and heat exchangers, and at rack manifolds. The PE100 fits that space while matching the electrical interfaces OEMs already use, from ratiometric voltage to Modbus.
For general industrial use Supmea offers the SUP-P300 (IP68 option), and for flow and level by differential pressure the SUP-2051 series.
Technical specifications
| Pressure type | Gauge, absolute, sealed |
|---|---|
| Range | −100 kPa to 60 MPa |
| Accuracy | Class 0.2, 0.25 or 0.5 |
| Long-term stability | ±0.2% FS/year |
| Medium temperature | −20 to 85 °C |
| Output | 4–20 mA; 1–5 V; 0–5 V; 0–10 V; 0.5–4.5 V; RS485 Modbus |
| Response time | T90 ≤10 ms (analog); ≤100 ms (RS485) |
| Power supply | 10–32 VDC (4–20 mA); 8–32 VDC (0–5/1–5 V); 12–32 VDC (0–10 V); 5 VDC (0.5–4.5 V) |
| Wetted materials | 316L diaphragm; 304/316L process connection; EPDM seal (FKM optional) |
| Electrical connection | Hirschmann, M12, cable or Packard |
| Overload / burst | 150% FS (≤10 MPa), 125% FS (>10 MPa) / 200% FS |
| Protection | IP65 |
Summarised from the official Supmea product page. The datasheet for your exact configuration governs. Ask us for it.
Key features
- Compact body for CDUs and skids
- Fast 10 ms response for pump control
- Ratiometric 0.5–4.5 V for OEM controllers
- EPDM seals compatible with water-glycol coolants
- Vibration and RF-interference resistant
Where it is used
- Data Center Liquid Cooling: CDU pump differential, filter ΔP and manifold pressure
- HVAC & District Energy: Chilled-water and condenser loops
- Water & Wastewater: Pump discharge and booster sets
- Food & Beverage: Utility water and air (non-hygienic points)
Frequently asked questions
Which output should I choose for a CDU controller?
Match the controller input. 4–20 mA is the most noise-immune over long cable runs; 0.5–4.5 V ratiometric suits 5 V OEM boards.
Gauge or sealed pressure?
Gauge references local atmosphere through a vent; sealed references a fixed internal pressure and suits high ranges or wet locations. See our pressure types article.
Related questions
- Gauge vs absolute vs differential pressure transmitter: what is the difference?Pressure
A gauge pressure transmitter measures relative to local atmospheric pressure (0 when open to air). An absolute transmitter measures relative to a perfect vacuum, so it…
- How do you choose a flow meter for data center liquid cooling?Liquid cooling
Choose by loop and coolant. On the facility water side (FWS), a magnetic flow meter suits conductive chilled water in larger pipes. On the technology cooling side (TCS),…
Related instruments
Programmable Temperature Transmitter
Turns RTD or thermocouple signals into a clean two-wire 4–20 mA loop.
Liquid Turbine Flow Meter
Clean water, glycol, fuel and oils in small lines, 0.5%R accuracy.
60 GHz Radar Level Meter
Non-contact level for tanks and open water, ±5 mm with a 6° beam.