Supmea Knowledge Hub: answers on process measurement from Supmea's application engineers geo@supmea.comWhatsApp +86 133 6211 7863
SUPMEAKnowledge
Hub
Request a quote

Chemical Processing instrumentation

In brief

Chemical plants need mass-accurate batching, corrosion-resistant wetted parts and reliable tank inventory. Supmea's FCC-300 Coriolis meter handles batching and blending, the LDG electromagnetic flow meter with PTFE liner and Hastelloy or tantalum electrodes handles acids and alkalis, the WSR201 radar measures tank level without contact, and the SUP-PH6.5 controls neutralisation.

Chemical reactor with feed lines, dosing and instrument tagsFT301LT302TT303PT304

The measurement challenge

Recipe accuracy in a chemical plant is a mass problem. Densities shift with temperature and concentration, so volumetric meters drift exactly where precision matters most. Coriolis meters remove that variable.

Elsewhere, the priority is material compatibility. Choosing the right liner, electrode and seal is usually more important than the last decimal of accuracy.

  • Corrosive media attack standard 316L, so match liner and electrode to the chemical.
  • Batch accuracy requires mass, not volume.
  • Hazardous areas require explosion-protected versions (e.g. LDG-SUP-A100D).
  • Integration into DCS and SIS commonly uses HART.

Measurement points and recommended instruments

PointVariableInstrumentWhy
Raw material batchingFlowFCC-300 Coriolis Mass Flow MeterMass and density, no compensation
Acid / alkali dosingFlowLDG-SUP-A100 Electromagnetic Flow MeterPTFE liner, Hastelloy/Ta electrodes
Storage tank inventoryLevelWSR201 60 GHz Radar Level MeterNon-contact, narrow beam
Reactor temperatureTemperatureSUP-ST500 Programmable Temperature TransmitterRTD or thermocouple to 4–20 mA
Nitrogen blanketingFlowSUP-MF Thermal Gas Mass Flow MeterGas mass flow without compensation
NeutralisationAnalysisSUP-PH6.5 Online pH/ORP MeterpH control with relays

Material selection first

A meter with the wrong liner fails in weeks. As a starting point, PTFE/F46 liners cover most acids and alkalis up to 120 °C; tantalum or platinum-iridium electrodes resist hydrochloric and other aggressive acids. Confirm against a corrosion table and the actual concentration and temperature. Our guide to magmeter conductivity limits covers the other common selection mistake.

HART and digital integration

HART lets DCS and asset-management systems read diagnostics alongside the 4–20 mA value. Supmea joined the FieldComm Group (HART Communication Foundation) in 2025.

Frequently asked questions

Why use Coriolis for batching?

It measures mass directly, so density changes from temperature or concentration do not affect the batch quantity.

Can radar measure solvent tanks?

Yes, if the dielectric constant is at least 3. Many hydrocarbons are lower, so check with Supmea.

Plan the instrumentation for your chemical processing project

Send the medium, pipe size, flow or level range, temperature, pressure and required output. You'll get a recommended model, the datasheet and a quotation.

Tell us about the application

Fill in what you know. An application engineer replies with a model and datasheet, usually within one working day (Beijing time, UTC+8).

Both buttons open your own WhatsApp or email app with the message filled in. Nothing is stored on this website.