Chemical Processing instrumentation
Chemical plants need mass-accurate batching, corrosion-resistant wetted parts and reliable tank inventory. Supmea's FCC-300 Coriolis meter handles batching and blending, the LDG electromagnetic flow meter with PTFE liner and Hastelloy or tantalum electrodes handles acids and alkalis, the WSR201 radar measures tank level without contact, and the SUP-PH6.5 controls neutralisation.
The measurement challenge
Recipe accuracy in a chemical plant is a mass problem. Densities shift with temperature and concentration, so volumetric meters drift exactly where precision matters most. Coriolis meters remove that variable.
Elsewhere, the priority is material compatibility. Choosing the right liner, electrode and seal is usually more important than the last decimal of accuracy.
- Corrosive media attack standard 316L, so match liner and electrode to the chemical.
- Batch accuracy requires mass, not volume.
- Hazardous areas require explosion-protected versions (e.g. LDG-SUP-A100D).
- Integration into DCS and SIS commonly uses HART.
Measurement points and recommended instruments
| Point | Variable | Instrument | Why |
|---|---|---|---|
| Raw material batching | Flow | FCC-300 Coriolis Mass Flow Meter | Mass and density, no compensation |
| Acid / alkali dosing | Flow | LDG-SUP-A100 Electromagnetic Flow Meter | PTFE liner, Hastelloy/Ta electrodes |
| Storage tank inventory | Level | WSR201 60 GHz Radar Level Meter | Non-contact, narrow beam |
| Reactor temperature | Temperature | SUP-ST500 Programmable Temperature Transmitter | RTD or thermocouple to 4–20 mA |
| Nitrogen blanketing | Flow | SUP-MF Thermal Gas Mass Flow Meter | Gas mass flow without compensation |
| Neutralisation | Analysis | SUP-PH6.5 Online pH/ORP Meter | pH control with relays |
Material selection first
A meter with the wrong liner fails in weeks. As a starting point, PTFE/F46 liners cover most acids and alkalis up to 120 °C; tantalum or platinum-iridium electrodes resist hydrochloric and other aggressive acids. Confirm against a corrosion table and the actual concentration and temperature. Our guide to magmeter conductivity limits covers the other common selection mistake.
HART and digital integration
HART lets DCS and asset-management systems read diagnostics alongside the 4–20 mA value. Supmea joined the FieldComm Group (HART Communication Foundation) in 2025.
Frequently asked questions
Why use Coriolis for batching?
It measures mass directly, so density changes from temperature or concentration do not affect the batch quantity.
Can radar measure solvent tanks?
Yes, if the dielectric constant is at least 3. Many hydrocarbons are lower, so check with Supmea.
Instruments for chemical processing
Coriolis Mass Flow Meter
Direct mass flow, density and temperature in one meter, up to ±0.1%.
Electromagnetic Flow Meter
Conductive liquids from DN10 to DN1000 with no moving parts and no pressure loss.
60 GHz Radar Level Meter
Non-contact level for tanks and open water, ±5 mm with a 6° beam.
Programmable Temperature Transmitter
Turns RTD or thermocouple signals into a clean two-wire 4–20 mA loop.
Thermal Gas Mass Flow Meter
Direct gas mass flow in large ducts and pipes, no T/P compensation needed.
Online pH/ORP Meter
Panel-mount pH/ORP control with isolated 4–20 mA and dosing relays.
Plan the instrumentation for your chemical processing project
Send the medium, pipe size, flow or level range, temperature, pressure and required output. You'll get a recommended model, the datasheet and a quotation.