What is turndown ratio in a flow meter, and why does it matter?

By Supmea Application EngineeringPublished Topic: Flow
Short answer

Turndown ratio is the maximum flow divided by the minimum flow over which a meter stays within its stated accuracy. A meter rated 10:1 with a 100 m³/h maximum is accurate down to 10 m³/h. Higher turndown matters when flow varies widely, for example between night and day, or between part and full load. Size the meter so that normal flow sits in the middle of its range, not at the pipe size.

Key points

  • Turndown = Qmax ÷ Qmin at stated accuracy.
  • Published turndown often assumes reference conditions (density, viscosity).
  • Oversized meters spend most of their life near Qmin.
  • Compare turndown on the same accuracy basis.

Published values compared

Values below come from Supmea product specifications; check the conditions behind each figure.

Turndown ratio comparison of Supmea flow meters from published specificationsTurndown (log scale)1:110:1100:11000:1SUP-MF thermal (velocity)0.1–100 Nm/sMagmeter (0.5–5 m/s band)10:1 at stated accuracyFLC420 turbine DN15–DN20010:1SUP-LUGB vortex8:1 at reference densityFLC420 turbine DN106:1
Figure 1. Turndown ratio comparison of Supmea flow meters from published specifications. Illustration: Supmea application engineering.

Worked sizing example

A cooling loop runs 12 m³/h normally, 4 m³/h at night and 18 m³/h at peak. A DN50 FLC420 covers 4–40 m³/h (10:1), so night flow sits exactly at the minimum. A DN40 covers 2–20 m³/h and keeps all three points inside the range, with normal flow mid-scale. Choose DN40 with reducers, and check pressure drop.

What reduces real turndown

  • Density changes for vortex meters: the SUP-LUGB's 8:1 is stated at 1.2 kg/m³ gas and 1000 kg/m³ liquid.
  • Viscosity for turbine meters: above 5×10⁻⁶ m²/s, calibrate on the actual liquid.
  • Velocity limits for magmeters: below about 0.5 m/s the relative error grows.
  • Installation: poor straight run hurts low-flow accuracy most. See magmeter installation.

Related questions

Is turndown the same as rangeability?

They are used interchangeably; both mean the ratio of maximum to minimum accurate flow.

Which technology has the highest turndown?

Thermal mass meters on gas and Coriolis meters typically offer very wide ranges; check the accuracy statement across the range.

Sources and further reading

Product specifications quoted here are summarised from Supmea datasheets. Confirm the figures for your exact model before final design.

Get a selection and quotation from an application engineer

Send the medium, pipe size, flow or level range, temperature, pressure and required output. You'll get a recommended model, the datasheet and a quotation.

Tell us about the application

Fill in what you know. An application engineer replies with a model and datasheet, usually within one working day (Beijing time, UTC+8).

Both buttons open your own WhatsApp or email app with the message filled in. Nothing is stored on this website.