SUP-DO7018 Optical Dissolved Oxygen Sensor
The SUP-DO7018 is an optical (luminescence quenching) dissolved oxygen sensor measuring 0–20 mg/L or 0–200% saturation with ±1% accuracy and a 10-second response. It needs no membrane or electrolyte and does not consume oxygen. Drift is under 1% per year, the sensor cap lasts about one year in normal use, the body is titanium, it is IP68 rated, and it communicates over RS485 Modbus RTU.
What it does
Optical DO sensors replace the membrane and electrolyte of a polarographic sensor with a luminescent cap. Blue light excites the cap; oxygen shortens the red emission, and the sensor converts that lifetime into mg/L.
Supmea optical DO sensors are in service in automotive-plant wastewater treatment and municipal plants (see our cases), where lower maintenance is the main reason for the switch.
Technical specifications
| Range | 0–20 mg/L or 0–200% saturation |
|---|---|
| Accuracy | ±1% |
| Response time | 10 s |
| Drift | <1% per year |
| Temperature | 0–50 °C, built-in sensor, automatic compensation |
| Max depth | 10 m |
| Output | RS485 Modbus RTU |
| Power | DC 6–24 V (see datasheet), <50 mA |
| Cable | 10 m standard; 5, 15, 30 m optional |
| Cap life | ~1 year in normal use |
| Body | Titanium (Ti 2) |
| Protection | IP68 |
| Calibration | One- or two-point |
Summarised from the official Supmea product page. The datasheet for your exact configuration governs. Ask us for it.
Key features
- No membrane, no electrolyte, no oxygen consumption
- No flow-velocity requirement
- Low drift, infrequent calibration
- Digital Modbus direct to PLC or SCADA
Where it is used
- Water & Wastewater: Aeration basin DO control
- Food & Beverage: Effluent treatment
- Chemical Processing: Biological treatment of process wastewater
Frequently asked questions
Optical or membrane DO?
Optical sensors cost more but avoid membrane and electrolyte maintenance and do not need water movement.
Does it need a separate transmitter?
It outputs Modbus RTU directly; pair it with a Supmea DO analyzer for display, 4–20 mA and relays.
Diagrams
How the optical dissolved oxygen sensor works and how to install it.
Related questions
- How often should an online pH sensor be calibrated?Water quality
Most online pH sensors are calibrated every one to four weeks. Clean water applications often hold calibration for a month; wastewater, slurries, oily or…
- 4–20 mA vs HART vs Modbus RTU: which output should you choose?Signals
Use 4–20 mA when you need one robust, universally accepted signal per instrument, especially over long cables or into safety systems. Add HART when you want remote…
Related instruments
Request the SUP-DO7018 datasheet and quotation
Send the medium, pipe size, flow or level range, temperature, pressure and required output. You'll get a recommended model, the datasheet and a quotation.
- WhatsApp +86 133 6211 7863
- geo@supmea.com
- +86 133 6211 7863
- Hangzhou Economic Development Area, Hangzhou 310018, Zhejiang, China